ES Complex system Features
The ES Complex system is a combination of 2 biosensor technologies with 5 features and signal processing analysis managed by software.
Bio impedance biosensor features:
1. The Bio Impedance in Bipolar Mode sensor (EIS sensor) feature evaluates the segmental conductivity of the human body with low frequencies via 6 tactile electrodes. The signal processing analysis of the measurement provides estimated parameters related to tissue oxygen consumption , interstitial fluid Chloride ions density and interstitial fluid morphology .
2. The Bio Impedance in Tetra polar Mode (BIA sensor) feature evaluates the resistance and the reactance of the human body using a mono frequency (50KHz) via 4 tactile electrodes, to estimate body composition parameters (TWB, Fat Free mass, fat mass) according to predictive equations as commonly seen in peer reviews.
Spectrophotometry biosensor features:
3.The Pulse Oximeter (SpO2 sensor) displays SpO2%, pulse rate value and vertical bar graph pulse amplitude.
4. The Photoelectrical Plethysmograph or Digital Pulse Analysis (DPA sensor)’ feature is the signal processing analysis of the pulse waveform provided by the oximeter. The mathematical analysIs provides indicators to estimate the cardiovascular function and hemodynamics indicators with the blood pressure measurement.
5. The Heart Rate Variability (HRV sensor) feature, both in the time domain (statistical methods) and in the frequency domain (spectral analysis). Each QRS complex is detected and the so-called normal-to-normal (NN) or Rate-to-Rate (RR) intervals between adjacent QRS complexes are the result of sinus node depolarization. The signal processing analysis of the measurement provides indicators to estimate the ANS (Autonomic Nervous System) activity.
Indications or Intended use
In order to estimate the homeostasis process the ES Complex provides estimation and Historical Tracking of the following intended uses:
1. To display Spo2 %
2. To analyze the basic rhythms of the NN or RR intervals in heart rate variability (HRV), both in the time domain and in the frequency domain (short time 5 minutes). It provides mathematical analyses of the input of the sinus node depolarization and ANS activity indicators.
3. To analyze the pulse waveform by photoelectric plethysmography (PP), the second derivative of the photoelectric plethysmography and Pulse rate (short time 2 minutes). It provides mathematical analyses of the input of the SpO2% measurement and hemodynamic indicators.
4. To analyze the Galvanic skin responses (EIS) .It provides mathematical analysis of the bio impedance measurement and living tissue conditions .
5. Estimated body composition parameters (BIA).
The BIA is intended for use on subject over 7 years old.
The EIS will be used for children (over 5 years old ) and adult patients.
The HRV and DPA will be used only for adult patients (over 17 years old).
The device is not intended for use in continuous monitoring.
The system will be used by practitioners.
The E.S Complex shall be associated with the software Health Care Software Solution